Device Unavailable Message |
Title: |
Device Unavailable Message |
Environment: |
Computer Lane Monitor |
Applicable Version(s): |
1.01, 1.02 |
Issue: |
Computer Lane Monitor will not communicate |
Cause: |
Communication port is not configured correctly or when operating system has been upgraded. |
Solution: |
Requires re-configuring of the COM port.
1. Open file C:\Windows\CLMWIN.INI using notepad*. Select the 'All Files' in the File Type pull down.
[Installable ISAMs]
FoxPro 2.5=xbs200.dll
[DATABASE]
DEFAULT=C:\CLMWIN\SAMPLES.MDB
[COMMPORT]
PORT=COMM1
2. To reset the comm port change the [COMMPORT] section to the following:
[COMMPORT]
PORT=NONE
3. Save file
4. Open The Computer Lane Monitor Software. Click “OK” on the Brunswick Lane Monitor window. Click Configure on the File Toolbar. Select Communications and set COMM port to appropriate COMM. (1=Serial Port, 3=USB Port).
*For Windows 2000 PRO follow this path for locating the CLMWIN.INI file: C:\WINNT\CLMWIN.INI
For Windows XP: C:\Windows\Windows\CLMWIN.INI
|
|
|
|
|
|