String Pinsetter is on but will not Score with SES Controllers only
Environment:
String Pinsetter
Applicable Version(s):
With SES Control Boxes Only
Issue:
String Pinsetter is not scoring even though the pinsetter light is on and the pinsetter picks up the correct pins and cycles correctly.
Cause:
String Pinsetter Interface has had the "Pinsetter On / Scoring Enabled" switch turned to "Pinsetter On" while the pinsetter and scoring was in progress.
Solution:
  1. Turn the "Pinsetter On / Scoring Enabled" switch for that lane back to "Scoring Enabled" and then turn off the main power switch on the SES String Control box.
  2. Turn the main switch back on.
This will reset the SES electronics to see the pin fall data.

 

Applicable Files:
Related Information and Links:
Revision Date:
11/22/2016 - Released to KB