ArticlesArticles LoginLogin
DrillDown Icon Table of Contents
DrillDown Icon Center Network Systems
DrillDown Icon Lane Maintenance
DrillDown Icon Pinsetters
DrillDown Icon Brunswick String
DrillDown Icon 5-Pin String Machine Scores All Strikes or All Gutters
DrillDown Icon Modify 360 String Pinsetters with New Style Pit Curtain to Allow for Light Bowling
DrillDown Icon No Score is Posted on a Lane
DrillDown Icon No Score or Abnormal Score Delay up to 20 Seconds
DrillDown Icon One or More Pins Constantly Score Standing
DrillDown Icon String Pin Pinsetter Constantly Cycles
DrillDown Icon String Pin Settings
DrillDown Icon String Pin will not Turn on when Lane Issued by Sync
DrillDown Icon String Pinsetter is on but will not Score with SES Controllers only
DrillDown Icon Tom England Control Box - Ball Elevator Motor Control
DrillDown Icon V2 Slide-Out installation in Existing V1 Slide-Out Installations (360 String)
DrillDown Icon Pinsetter Lighting Systems
DrillDown Icon Stop Errors Associated with Reed Switch Signal
DrillDown Icon Scoring Systems
  Subscribe Email This ArticlePrint PreviewPrint Preview Current Article/Category with all Sub-Articles/Sub-Categories
 
String Pin will not Turn on when Lane Issued by Sync
Environment:
String Pin pinsetter 360 Control Box
Applicable Version(s):
All Sync with 360 Control Box software version less than 1.1.22
Issue:

The following items will occur indicating a 360 Control Box lock up(freeze).

  • String Pin pinsetter does not turn on when the lane is issued from the Sync system.
  • The 360 Control Box GUI will not display the options from the drop down box.

  • The heart beat LED on the 360 Control Box Slide-Out PCB will either be steady RED or OFF, and it is not blinking as a heartbeat.

  • There will be no pinsetter or pin deck lighting control from Sync desk.
Cause:
This seems to be the case when the system is not used, but still left running for a certain period of time. Although, the exact period of time the system is not used in order to cause this issue is unknown. However, it seems to be more prevalent in the residence installations where the system is more likely to be dormant for longer periods of time than an actual business that runs the strings pin pinsetters daily. We have seen this issue happen within 2 days of no use.
Solution:

The 360 Control Box Slide-Out PCB must have its firmware updated to minimum version 1.1.22 in order to prevent further lock ups caused by long period of dormant use.

 

If the 360 Control Box Slide-Out cannot be flashed with updated firmware at the location by a Brunswick representative, then send the 360 Control Box Slide-Out PCB only back to Brunswick to have the firmware updated to a version 1.1.22 or higher.

Removal of the 360 Control Box Slide-Out tray is obtained by loosening 8 Phillips head screws and gently sliding the tray towards you.

 

Temp Fix: If a lock up occurs, cycling power to the machine should clear it up temporarily and present a Slide out PCB heartbeat that is expected.

Applicable Files:
Contact Brunswick for Firmware updates to a 360 Control Box.
Related Information and Links:
360 Control Box Slide-Out PCB (part # 55-860058-400)
Revision Date:
7/14/16 - Released to KB

 
Modified 10/7/2019